Rev Sci Tech ; 33(3): 869-75, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25812210

RESUMO

The complement fixation test (CFT) is the only serological test prescribed by the World Organisation for Animal Health (OIE) for the diagnosis of glanders in international trading of equids. However, false-positive reactions have caused financial losses to the animal owners in the past, and false-negative tests have resulted in the introduction of glanders into healthy equine populations in previously glanders-free areas. Both warm (incubation at 37°C for 1 h) and cold (overnight incubation at 4°C) procedures are recommended by the OIE for serodiagnosis of glanders. In a comparison of the sensitivity and specificity of the two techniques, using the United States Department of Agriculture antigen, warm CFT was found to be significantly less sensitive (56.8%; p < 0.0005) than the cold CFT (83.6%). Cold CFT thus increases the detection rate of glanders but a lower diagnostic specificity has to be accepted. The immunoblot was used as the gold standard.


Assuntos
Testes de Fixação de Complemento/veterinária , Mormo/diagnóstico , Temperatura , Animais , Antígenos de Bactérias , Testes de Fixação de Complemento/métodos , Mormo/microbiologia , Sensibilidade e Especificidade